Outline-SR-LEDW-5N
This product is a new top-end model in Topcon Spectroradiometer, which has capability of measuring wide dynamic range from ultra-low luminance of 0.0005cd/m² to ultra-high of 5,000,000cd/m². Addition to the new FIX mode, the SR-LEDW calculates optimum measuring setting automatically and reduces the measuring time in continuous measurement of the same object. This product can be used with high speed and high accuracy not only in the Design/Development department but also in quality control in production line of LED module. |
Features
|
Applications
|
Specifications
Photo detector | Electronically cooled linear CCD |
---|---|
Dispersing element | Diffraction grating |
Optical system | Object lens : f= 82mm F2.5, Collimation lens : Range of view= 5° |
Measurement angle | 2°/1°/0.2°/0.1° selectable (Motor moved) |
Measurement distance | 350mm - ∞ (distance from metallic tip of objective lens) |
Spectral bandwidth | 5nm *Half bandwidth |
Wavelength accuracy | ±0.3nm *Hg emission lamp |
Wavelength range | 380~780nm |
Wavelength resolution | 1nm |
Measurement mode | Auto/Manual(integral time/frequency) / External vertical sync signal input |
Measurement object | Spectral radiance : W・sr-1・m-2・nm-1 |
Calculation function | Radiance Le : W・sr-1m-2、 Luminance Lv : cd・m-2 CIE1931 chromaticity coordinates xy,、CIE1976 chromaticity coordinates u' v', Tristimulus value XYZ,' Correlated color temperature and Deviation, CIE standard observer 2°/ 10° |
Range of guaranteed illuminance accuracy(*1)(*2) | 2.0°: 0.0005~1,500,000、 1.0°: 0.0015~4,500,000 0.2°: 0.0375~5,000,000、 0.1°: 0.15~2,000,000 |
Accuracy in luminance(*1) | ±2% or less |
Accuracy in chromaticity(x,y) (*1) | ±0.002 |
Repeatability in luminance(*3) | 1.5% : 0.0005~0.005cd/m² 0.4% : 0.005~0.1cd/m² 0.3% : 0.1 cd/m²以上 |
Accuracy in chromaticity(*4) | 0.005 : 0.0005~0.005cd/m² 0.0015 : 0.005~0.1cd/m² 0.0005 : 0.1 cd/m²以上 |
Polarization error | Luminance 1% or less, Spectral radiance 2% or less (400 - 780nm) |
Measurement time(*5) | NORMAL Mode: about 1 - 248sec, HIGH SPEED Mode: about 1 - 17sec |
Interface | RS-232C、 USB 2.0 |
Power supply | Dedicated AC adapter AC100V-240V, 50/60Hz, DC12V36W |
Power consumption | about 36W |
Use conditions | Temperature: 5 - 30℃, Humidity: 80%RH or less (no condensation) |
Outer dimensions (W×D×H) | 150×406×239mm |
Weight | 5.5kg |
(*1) : For standard illuminance A (*2) : Measurable range in Normal and High speed mode. (*3) : 2σ from 10 times continuous measurement at measuring angle 2°in normal speed mode. (*4) : Max – Min) value from 10 times continuous measurement at measuring angle 2°in normal mode. (*5) : Except communication time with PC |
Measurement area (Diameter φ)
(mmφ) |
Measurement angle | Measurement distance(*1) | ||||
---|---|---|---|---|---|
350mm | 500mm | 800mm | 1000mm | 2000mm | |
2° | 10 | 15.1 | 25.4 | 32.2 | 66.4 |
1° | 4.99 | 7.55 | 12.7 | 16.1 | 33.2 |
0.2° | 1 | 1.51 | 2.54 | 3.22 | 6.64 |
0.1° | 0.5 | 0.76 | 1.27 | 1.61 | 33.2 |
(*1) : The measurement distance is the distance from the tip of the metal fixture on the instrument of the objective lens. |
Available Accessories
|
: AL-6/AL-11/AL-12 |
|
: WS-3 |
|
: IA-2 |
|
: FP-3P |
|
: Tripod5N |
|
: Tripod-SR |
|
: S-4 |
|
: ND-10/100 |
|
: ZV-30 |